Anti-slip coating is not a single category. It covers several different product chemistries each targeting a different surface and a different problem. Applying a food-safe floor coating to polished concrete expecting the same result as a chemical micro-texture treatment will produce the wrong outcome. Understanding what each coating type does, and to which surfaces it bonds, is the prerequisite for specifying correctly.
This guide covers the main anti-slip coating types available in Australia, how surface chemistry determines which product applies, and what compliance requirements govern their use.

Why Not Every Coating Works on Every Surface
Coatings work by bonding to the surface at a chemical level or by adding a physical layer that changes surface texture. Whether that bond holds depends on the chemistry of both the coating and the substrate.
Three factors determine compatibility:
- Surface porosity: porous surfaces like concrete absorb the coating and create a mechanical bond. Non-porous surfaces like sealed tiles require a coating that etches the surface rather than penetrating it.
- Surface chemistry: acid-sensitive surfaces cannot accept acid-etch treatments. Chemical contamination (oils, waxes, sealants) prevents most coatings from bonding to the substrate.
- Surface condition: a coating applied over a deteriorating surface will only be as durable as what it is sitting on.
Getting the surface assessment right before specifying the coating is not an optional step. It is what determines whether the coating lasts one year or five.
The Main Anti-Slip Coating Types and What They Target
Coating Type | Target Surface | Mechanism | Typical Setting |
Liquid micro-texture treatment | Concrete, ceramic tile, natural stone | Chemical etch or micro-texture | Commercial, retail, hospitality |
Epoxy and resin-based coating | Concrete, screeds, industrial floors | Physical layer with aggregate | Industrial, warehouse, food processing |
Food-safe wet-area coating | Tiles, stainless steel, wet zone surfaces | Bonded non-slip layer, chemically inert | Commercial kitchens, food processing |
Liquid Micro-Texture Treatments
Liquid micro-texture treatments are the invisible solution. The treatment reacts with or etches the surface to create micro-roughness that increases grip without adding any visible material. The surface looks the same after treatment.
Used on:
- Sealed and polished concrete
- Ceramic and porcelain tiles
- Natural stone including granite, slate and marble
- Glazed surfaces where appearance must be preserved
The UltraGrip liquid treatment is formulated for hard, non-porous surfaces. It is the correct specification where an adhesive strip or physical tread would be rejected on appearance or profile grounds. For commercial hospitality settings, retail floors and heritage surfaces, a micro-texture treatment preserves the surface aesthetic while reducing slip risk.
Not suitable for:
- Timber or wood surfaces
- Painted surfaces
- Any substrate that is not chemically compatible with the treatment formulation
- Surfaces contaminated with oil, wax or sealant that prevents chemical contact
For a detailed breakdown of anti-slip coating for bathroom tiles and similar surfaces, the tile surface specification covers application method, reapplication frequency and product limitations.
Epoxy and Resin-Based Coatings
Epoxy coatings add a physical layer to the floor that incorporates anti-slip aggregate, typically quartz, aluminium oxide or carborundum grit. The coating bonds to the concrete or screed substrate and provides a durable, grip-rated surface across the whole floor area.
Used on:
- Concrete warehouse and industrial floors
- Loading docks and vehicle access areas
- Workshops and manufacturing floors
- Any large-area floor where grip, durability and chemical resistance are all required
The grip level is controlled by the aggregate size and concentration in the coating mix. A higher aggregate loading provides more grip but is harder to clean. This trade-off matters in food processing and similar environments where floor hygiene is a compliance requirement.
For anti-slip coating for concrete surfaces, the concrete preparation requirements before epoxy application are as important as the coating selection. Shot-blasting or mechanical scarifying is typically required to create the surface profile that allows epoxy to bond correctly.
For epoxy floor coating options, the range covers different aggregate profiles for different grip and hygiene requirements.
Food-Safe Coatings for Wet Environments
Food-safe anti-slip coatings are a specific sub-category formulated to meet food hygiene requirements: non-toxic, chemically inert, cleanable with commercial food-safe detergents and resistant to the temperature cycling of commercial kitchen environments.
Used on:
- Commercial kitchen floors and preparation areas
- Food processing and cold storage facilities
- Wet rooms in food retail environments
Standard anti-slip coatings may not meet food safety legislation requirements even if they provide adequate grip. The SaniGrip coating for food-safe and wet environments is specifically formulated for wet, food-contact-adjacent applications where standard epoxy or liquid treatments are not appropriate. Confirm food-safety certification requirements with GripFactory for your specific application before specifying.
Not sure which coating suits your surface type? Browse GripFactory’s anti-slip coating range.
Surface Compatibility: Matching the Coating to the Substrate
Correct surface matching prevents product failure and avoids costly re-application. The table below covers the most common surfaces and the coating types that apply to each.
Surface | Liquid Treatment | Epoxy/Resin | Food-Safe Coating |
Polished concrete | Excellent | Excellent (prep required) | Good |
Standard concrete | Good | Excellent | Good |
Ceramic tiles | Excellent | Not typical | Good |
Porcelain tiles | Check product rating | Not typical | Good |
Natural stone | Check product rating | Not typical | Not typical |
Stainless steel | Not suitable | Not suitable | Check product rating |
Painted surfaces | Not suitable | Not suitable | Not suitable |
For anti-slip treatments on polished concrete floors, the polished surface presents a different challenge to standard concrete. The densified surface layer may resist micro-texture treatments that work well on standard concrete, requiring a specific formulation or surface preparation step before treatment.
For ceramic tile surface options and treatments, tile-specific liquid treatments are available that account for the glaze chemistry of different tile types.
Application and Surface Preparation
Coating performance depends on surface preparation as much as product selection. The same coating applied to a correctly prepared surface versus an unprepared one will produce a significant difference in lifespan and grip retention.
The preparation steps that apply regardless of coating type:
- Degrease: remove all oil, wax, sealant, cleaning product residue and contamination.
- Profile the surface: for epoxy, mechanical profiling is typically required. For liquid treatments, confirm whether the surface requires acid etching or mechanical prep.
- Dry completely: coating applied over damp concrete or hard floor surfaces will not bond correctly.
- Test compatibility: apply to a small test area first, particularly on stone, tile or any surface with an unknown coating history.
- Follow cure times: coating should not be trafficked until fully cured per the product specification.
Browse the full coating range for product-specific application guides, or the liquid treatments range for micro-texture and chemical treatment options.
Compliance and What the Standards Actually Require
Standard | What It Covers | When It Applies |
Slip resistance classification for pedestrian surfaces including coatings | All coatings used in commercial or public buildings | |
Slip resistance assessment of existing pedestrian surfaces | When assessing a coated surface after application | |
Accessible pathway and surface requirements | Public buildings and accessible facilities |
AS 4586 is the primary reference for coating specification. A coating sold as anti-slip does not automatically carry an AS 4586 classification. Confirm the product’s P-rating matches the intended use before specifying for a regulated space: wet or dry, barefoot or shod. AS 4663 provides the method for testing a surface after coating to confirm it meets the required classification.
If You Are Still Not Sure Which Coating, Start Here
The decision tree is short:
- Appearance must be preserved, non-porous surface: liquid micro-texture treatment
- Large-area concrete floor, industrial or warehouse: epoxy or resin-based coating
- Wet zone with food safety requirement: food-safe coating
- Tile surface, wet or dry: liquid treatment or food-safe coating depending on the setting
- Fast interim solution needed: anti-slip tape options while a coating solution is being specified and prepared
For anything that does not fit cleanly into these categories, surface compatibility testing before full application is the correct process. A small test patch costs less than a full re-application.
Explore the full anti-slip product range across coatings, liquid treatments and tape solutions. GripFactory can advise on coating selection for specific substrates and compliance requirements. Contact the team before committing to a full application on a surface you have not previously treated.
FAQs
Anti-slip coating bonds to the surface through a chemical or physical mechanism, changing the grip properties of the substrate itself without adding a removable strip. Anti-slip tape is a physical adhesive strip that adds grip through its abrasive upper face. Coating is invisible and better suited to surfaces where a tread strip is not acceptable aesthetically or practically; tape is faster to apply and easier to replace.
Lifespan depends on the coating type, foot traffic and cleaning method. As a general guide, liquid micro-texture treatments on moderate-traffic surfaces may last one to three years before grip diminishes to a level requiring reapplication. Epoxy coatings on industrial floors, correctly applied, typically last considerably longer but should be inspected annually for surface wear and delamination around the edges.
Yes. Anti-slip coatings in commercial and public buildings should carry an AS 4586 slip resistance classification appropriate for the wet or dry conditions and footwear type expected. After application, AS 4663 provides the method for testing the coated surface to confirm it meets the required classification. A product described as anti-slip without a verified P-rating does not satisfy the compliance requirement.
No. Paint is a contaminating layer that prevents most coatings from bonding to the substrate beneath. A coating applied over paint will delaminate with the paint rather than bonding to the floor. Painted surfaces require the paint to be mechanically removed before any coating treatment, which changes the scope and cost of the job significantly.
Some coatings are rated for outdoor use and some are not. Liquid micro-texture treatments vary by formulation. Confirm outdoor and UV rating before specifying for an exposed surface. Epoxy coatings can be formulated for outdoor use but require UV-stable resins. Standard interior epoxy will yellow and degrade under UV. Always confirm outdoor suitability from the product documentation rather than assuming.