A ladder rung is twelve centimetres wide and gets used one foot at a time. When it is worn, contaminated with oil or just wet from rain, the risk of a fall is significant and the employer’s duty of care is equally significant. Anti-slip treatment on ladder rungs is not an optional upgrade. For fixed access ladders in Australian workplaces, it is a WHS obligation.
This guide covers the product options for ladder rung safety, the difference between fixed and portable ladder requirements, and what Australian Standards require for compliant installations.

Why Ladder Rungs Are One of the Most Overlooked Slip Hazards on Site
Stair treads get attention because they are visible and high-traffic. Ladder rungs get overlooked because they are used less often, often only when something needs fixing.
That infrequency is exactly the problem. Rungs that are only used occasionally tend to accumulate contamination between uses, and the person climbing them is often carrying tools or wearing gloves, which reduces grip further.
The three most common causes of rung-related slip incidents are:
- Surface contamination from oil, grease, water or mud
- Worn or damaged rung surfaces that have lost their original grip profile
- No anti-slip treatment at all on older or non-standard ladders
None of these require a significant budget to fix. They do require a systematic approach to identifying which ladders need treatment and specifying the right product for each.
What Products Exist for Ladder Rung Safety
Three product formats apply to ladder rungs. The right choice depends on the rung profile, the material and the level of exposure on site.
Product | Rung Profile | Best For | Not Suited To |
Moulded GRP rung covers | Round and D-rung profiles | Fixed access ladders, industrial | Flat rungs, low-clearance applications |
Anti-slip tape | Flat rungs, retrofit, temporary | All ladder types, fast application | Heavy contamination without prep |
Replacement rung surfaces | Flat and square profiles | Full refurbishment, new installations | Quick fixes, existing round rungs |
Moulded GRP Rung Covers
GRP rung covers are the most durable solution for fixed access ladders. They sleeve over the existing rung, providing a full-circumference grip surface that holds up to oil, water and boot traffic. The moulded GRP profile means there is no adhesive to fail and no tape edge to lift.
Used on:
- Fixed vertical access ladders on mezzanines, tanks and plant structures
- Ship’s ladders and inclined fixed ladders
- Any fixed ladder where permanent, low-maintenance anti-slip is required
The 22mm round-profile rung cover in safety yellow is a standard specification for round-rung fixed ladders where high visibility is also required. For the full ladder rung anti-slip product range, a detailed overview of rung cover products and how they are applied on site covers the installation process in detail. Profiles are available in different diameters and colours to suit common rung sizes.
Anti-Slip Tape for Rungs
Anti-slip tape is the fastest application method for ladder rungs and suits both round and flat rung profiles when the correct tape format is used. Flexible tape is required for round rungs. Standard rigid tape will bridge the curve and lift at the edges within weeks.
Used on:
- Portable ladders requiring an anti-slip upgrade
- Flat-rung fixed ladders where rung covers are not the right fit
- Temporary or interim treatment on any rung type
Coarse tape for rung surfaces where covers are not viable provides the grip level appropriate for safety boots in industrial settings. For a broader view of tape options for fixed and portable ladders, format, width and adhesive type all affect which product suits each rung configuration.
Need anti-slip covers for ladder rungs at your site? Browse GripFactory’s PolyGrip ladder rung covers.
Replacement Rung Surfaces
Full rung replacement is the correct approach when the existing rung is structurally compromised, worn beyond surface treatment or part of a planned refurbishment. This is typically handled as part of a broader access equipment maintenance program rather than a standalone anti-slip measure.
This is not covered in this guide. If you are at the point of rung replacement, the structural and fabrication requirements sit outside the scope of anti-slip surface product selection.
Fixed vs Portable Ladders: Different Hazards, Different Obligations
Fixed and portable ladders are governed by different standards and carry different WHS implications. The distinction matters for product selection.
Ladder Type | Governed By | WHS Obligation | Product Implication |
Fixed access ladder (permanent) | Employer must maintain to standard | Durable rung covers or replacement preferred | |
Portable ladder (user-moved) | Employer must ensure ladder is safe for use | Tape or covers both viable | |
Ship’s ladder (fixed inclined) | AS 1657 | Same as fixed access | Durable product required |
For fixed access ladders, the employer has an ongoing maintenance obligation under WHS legislation. Anti-slip treatment applied once and never inspected does not satisfy that obligation. Inspection records, replacement schedules and product documentation all form part of a defensible WHS position if an incident occurs.
For anti-slip plates and grating solutions for access platforms adjacent to ladders, the platform and ladder system together form the access route. Treating the ladder rungs without addressing the platform landing surface is a partial solution.
What AS 1657 Requires for Fixed Access Ladders
AS 1657 is the primary standard governing fixed platforms, walkways and stair and ladder design in Australian industrial settings. Its requirements for ladder rungs are specific:
Requirement | AS 1657 Specification | Notes |
Rung diameter | Minimum 20mm for round rungs | Affects which rung cover profiles fit |
Rung spacing | 225mm to 300mm centre-to-centre | Not a surface treatment requirement |
Slip resistance | Grip surface required on all rungs | Product must be appropriate for the contamination risk |
Rung width | Minimum 400mm for fixed ladders | Determines rung cover or tape length required |
The standard does not specify a particular product. It requires a grip surface appropriate for the use, meaning the employer must assess the contamination risk (wet, oily, dry), the footwear type and the frequency of use to determine what product is appropriate. A rung cover or tape that meets the grip requirement for dry boot use may not be sufficient in an oily plant environment.
For steel grid and platform surface options associated with fixed ladder access, the full access route should be assessed together. For an overview of anti-slip plates for industrial safety applications at platform level, treating the whole access route as one specification reduces the risk of a compliant ladder feeding onto a non-compliant landing.
Your WHS Obligation Does Not End at the Bottom of the Ladder
Most ladder incidents happen at the top or bottom, not on the rungs themselves. The transition from ladder to platform, and from floor to first rung, are the highest-risk points. Anti-slip treatment on rungs is necessary, but it is one part of a compliant access system.
A complete ladder anti-slip programme covers:
- Rung surfaces: correct product for the rung profile and contamination risk
- Platform landing: anti-slip treatment on the surface the worker steps onto at the top
- Base area: clear, anti-slip surface at the base of the ladder (see concrete and hard floor surface options for treatment products)
- Inspection schedule: documented checks at a frequency appropriate to the use level
For access platform tread solutions adjacent to ladders and for warehouse floor and access route anti-slip strategy, treating the full access system rather than just the rungs is the difference between a compliant installation and a partial fix that leaves risk unaddressed.
GripFactory stocks rung covers, tape and plate solutions for the full fixed ladder access system. Browse the complete anti-slip product range for all formats across ladders, stairs and platforms. If you are specifying anti-slip treatment for a fixed ladder installation, contact the team for confirmation that the product suits your rung profile and contamination conditions before ordering.
FAQs
Moulded GRP rung covers that sleeve over the existing rung are the most durable solution for round steel rungs. They provide full-circumference grip, require no adhesive and hold up to oil, water and heavy boot traffic. Flexible anti-slip tape is a viable alternative for retrofits where rung covers are not practical, provided the tape is specifically rated for curved surfaces.
Fixed access ladders in Australian workplaces must comply with AS 1657, which requires a grip surface on all rungs appropriate for the contamination risk at the site. Employers have an ongoing WHS obligation to maintain that grip surface and document inspections. Portable ladders are governed by AS/NZS 1892 and carry a separate obligation to ensure the ladder is safe for use before each operation.
Tape lifting on ladder rungs is almost always caused by surface contamination or using a rigid tape on a curved rung. Clean and degrease the rung surface thoroughly before application, use flexible tape on round profiles, and apply with firm roller pressure. In environments with ongoing oil or chemical exposure, moulded rung covers bonded mechanically are a more reliable long-term solution than tape.
Inspection frequency depends on the use level and contamination risk. As a general guide, monthly visual inspection is appropriate for regularly used fixed access ladders, with a formal documented check quarterly. Ladders in high-contamination environments such as food processing or oil and gas should be inspected more frequently. WHS legislation requires that inspection records be kept as part of a defensible safety management system.
Not always. Rung covers are profile-specific and only fit the rung diameter they are designed for. Anti-slip tape can be used on both, provided the correct format is selected for each surface profile. For stair treads, full-depth composite treads offer better coverage and longevity than tape in high-traffic settings. For rungs, the narrower contact area and curved profile make rung-specific products the more reliable specification.